Description The chassis process (chassisd) detected the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Perform any corrective actions mentioned in the error message.
CHASSISD_GENERIC_WARNING
System Log Message function-name: error-message
Description The chassis process (chassisd) generated the indicated warning message.
Type Error: An error occurred
Severity notice
Facility LOG_DAEMON
CHASSISD_GETTIMEOFDAY
System Log Message Unexpected error from gettimeofday: error-code -- error-message
Description The chassis process (chassisd) could not obtain the time of day because of the indicated
error.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
CHASSISD_GRES_UNSUPP_PIC
System Log Message Unable to enable graceful Routing Engine switchover; PIC does not support it
Description The chassis process (chassisd) could not enable graceful Routing Engine switchover
because an installed PIC does not support it.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_HIGH_TEMP_CONDITION
System Log Message Chassis temperature over temperature degrees C (message)
Description The temperature of one or more components (field-replaceable units, or FRUs) exceeded
the indicated temperature, which is the lower of two thresholds. The fans (and impellers,
if applicable) were in the indicated state. The chassis process (chassisd) increased the
speed of all functioning fans and impellers to full speed.
Copyright © 2010, Juniper Networks, Inc.168
Junos 10.3 System Log Messages Reference