Facility LOG_DAEMON
CHASSISD_MALLOC_FAILURE
System Log Message function-name: chassisd malloc failed, aborting
Description The chassis process (chassisd) could not allocate memory. The chassisd process tried
to continue functioning, but the lack of memory usually causes the process to fail. An
administrator needs to restart it at some point.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_MASTER_PCG_REMOVED
System Log Message Master PCG (slot pcg-slot) removed; powering down Packet Forwarding Engine complex
Description The master Packet Forwarding Engine Clock Generator (PCG) was removed. The PCG
provides the system clock for all application-specific integrated circuits (ASICs) in the
routing platform, so packet forwarding halts until the Packet Forwarding Engine is
restarted and a PCG is functioning as master.
Type Error: An error occurred
Severity critical
Facility LOG_DAEMON
CHASSISD_MASTER_SCG_REMOVED
System Log Message Master SCG (slot fru-slot) removed; powering it down
Description The master SONET Clock Generator (SCG) was removed. The SCG provides the clock
for SONET/SDH interface timing, so those interfaces might drop packets and experience
other errors until a new clock source is established.
Type Error: An error occurred
Severity critical
Facility LOG_DAEMON
CHASSISD_MBUS_ERROR
System Log Message fru-name fru-slot: management bus failed sanity test
Description Startup tests on the indicated FRU's management bus failed.
Type Error: An error occurred
Severity error
185Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages