Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
CHASSISD_PIC_SPEED_INVALID
System Log Message Set speed for so-fpc-slot/pic-slot/port to default-value because configured value
current-value is invalid
Description The chassis process (chassisd) set the speed for the indicated PIC to the indicated value,
because the configured value is either higher than the maximum valid value or lower than
the minimum valid value.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Reconfigure the PIC with a valid speed.
CHASSISD_PIC_VERSION_ERROR
System Log Message Hardware version (pic-slot) of PIC fpc-slot in FPC pic-type (PIC type version) is not
supported
Description The chassis process (chassisd) did not bring the indicated PIC online, because its hardware
version is not supported.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
Cause The PIC requires a hardware upgrade.
Action Contact your technical support representative.
CHASSISD_PIDFILE_OPEN
System Log Message Unable to open PID file 'filename': errno error-code
Description The chassis process (chassisd) could not open the file where it stores its process ID (PID).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause The chassisd process might have detected that another chassisd process was running
and tried to read the file so that it could use the PID recorded there when terminating the
other process.
Copyright © 2010, Juniper Networks, Inc.194
Junos 10.3 System Log Messages Reference