CHASSISD_PIPE_WRITE_ERROR
System Log Message Pipe write error: error-message
Description The chassis process (chassisd) experienced a fatal error while writing to a pipe.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause There is no reader for the pipe.
CHASSISD_POWER_CHECK
System Log Message fru-name fru-slot not powering up
Description The chassis process (chassisd) could not power up the indicated component
(field-replaceable unit, or FRU), because the FRU did not respond.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_POWER_EVENT
System Log Message Unable to turn off power to fru-name fru-slot; a stand-alone test jumper might be installed
Description The chassis process (chassisd) could not turn off power to the indicated component
(field-replaceable unit, or FRU).
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause A common reason is that a standalone test jumper is installed.
CHASSISD_POWER_RATINGS_EXCEEDED
System Log Message PIM/module in slot fru-slot left offline to avoid exceeding chassis power ratings
Description The chassis process (chassisd) did not bring online the component (field-replaceable
unit, or FRU) in the indicated slot, because doing so causes the total power demand of
components in the chassis to exceed the chassis' power ratings. On a J-series Services
Router, the component is a Physical Interface Module (PIM) or other module that installs
in a PIM slot.
Type Error: An error occurred
Severity error