Severity error
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_RE_OVER_TEMP_SHUTDOWN
System Log Message Routing Engine routing-engine-slot temperature above threshold degrees C for too long;
action
Description The chassis process (chassisd) performed the indicated action because the temperature
of the indicated Routing Engine exceeded the maximum threshold for more than four
minutes. Continued operation at the excessive temperature could damage routing
platform components.
Type Error: An error occurred
Severity critical
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_RE_OVER_TEMP_WARNING
System Log Message Routing Engine routing-engine-slot temperature (temperature C) over threshold degrees
C, component will shutdown in duration seconds if condition persists
Description The temperature of the indicated Routing Engine exceeded the indicated temperature,
which is the upper of two thresholds. If the temperature does not go below the threshold
within four minutes after the chassis process (chassisd) detects this condition, the
chassisd process shuts down the indicated component. When this message was logged,
the indicated number of seconds remained before shutdown.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_RE_WARM_TEMP_CONDITION
System Log Message Routing Engine routing-engine-slot temperature (temperature C) is above warm
temperature limit (threshold C)
Description The temperature of the indicated Routing Engine exceeded the indicated temperature,
which is the lower of two thresholds.
Type Event: This message reports an event, not an error
Severity error
199Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages