Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_ROOT_MOUNT_ERROR
System Log Message Unable to determine the mount point for root directory: error-message
Description The chassis process (chassisd) could not determine the mount point for the root file
system.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_RTS_SEQ_ERROR
System Log Message ifmsg sequence gap expected-value - received-value
Description The chassis process (chassisd) received a routing socket message out of order.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause A routing socket message was lost because of excessive load or lack of memory.
CHASSISD_SBOARD_VERSION_MISMATCH
System Log Message Version mismatch: chassisd message version expected-value fru-name message version
received-value local IPC version local-ipc-version remote IPC version remote-ipc-version
Description The chassis process (chassisd) verifies that it supports the revision level or version of a
component (field-replaceable unit, or FRU). The revision level for the indicated FRU was
unsupported or otherwise invalid.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause Either a previous software upgrade did not complete successfully, or the chassisd process
or FRU did not restart after a successful software upgrade.
Action Upgrade the software and reboot the routing platform.
CHASSISD_SENSOR_RANGE_NOTICE
System Log Message fru-name fru-slot temperature is temperature degrees C, which is outside operating range
Copyright © 2010, Juniper Networks, Inc.200