Description The temperature sensor on the indicated component (field-replaceable unit, or FRU)
reported the indicated temperature, which is outside the acceptable operating range.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause Some sensors generate erroneous readings when a FRU starts up. When this happens,
the chassis process (chassisd) rereads the sensor at a later time.
CHASSISD_SERIAL_ID
System Log Message Serial ID read error: error-code -- error-message
Description The chassis process (chassisd) could not obtain the Routing Engine's serial number from
the kernel because of the indicated error.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
CHASSISD_SFM_MODE_ERROR
System Log Message function-name: error-message
Description The chassis process could not configure a requested operational mode for a Switching
and Forwarding Module (SFM), for the indicated reason.
Type Error: An error occurred
Severity info
Facility LOG_DAEMON
Cause Possible reasons include (a) the requested mode is available only with certain versions
of an application-specific integrated circuit (ASIC) (b) not all SFMs are online as required
by the requested mode (c) cross-connect mode cannot be configured if an OC-192c PIC
is installed.
CHASSISD_SFM_NOT_ONLINE
System Log Message function-name: SFM sfm-slot not online
Description The indicated Switching and Forwarding Module (SFM) was offline.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
201Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages