CHASSISD_SHUTDOWN_NOTICE
System Log Message Shutdown reason: reason
Description Although the chassis process (chassisd) normally does not exit or shut down except
when the Routing Engine reboots, it shut down for the indicated reason.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
CHASSISD_SIB_INVALID_SLOT
System Log Message fru-name in invalid slot slot
Description The chassis process (chassisd) detected the presence of the switch interface board
(SIB) in an invalid slot. The SIB remains offline.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_SIGPIPE
System Log Message SIGPIPE received
Description The chassis process (chassisd) received a signal indicating that its attempt to write to
a pipe failed because the reader (which could be another process or thread) did not exist.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
Cause The entity at the other end of the pipe exited or closed the connection.
CHASSISD_SMB_ERROR
System Log Message smb_read: fpga download not complete: val return-value, action
Description The system management bus (SMB) could not download field-programmable gate array
(FPGA) information and returned the indicated status code. The chassis process
(chassisd) took the indicated action.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON