Facility LOG_DAEMON
CHASSISD_SYSCTL_ERROR
System Log Message function-name: sysctl-error error from sysctl-function-name: error-message (errno
error-code)
Description The chassis process (chassisd) received the indicated error from the indicated sysctl()
operation.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_TEMP_HOT_NOTICE
System Log Message fru-name temperature of temperature degrees C is above limit (threshold degrees)
Description The temperature of the chassis, or of the indicated component (field-replaceable unit,
or FRU), exceeded the lower of two thresholds. The chassis process (chassisd) increased
the speed of all functioning fans (and impellers, if applicable) to full speed. If the
temperature did not decrease below the threshold within 4 minutes after this message
was logged, the chassisd process shut down the routing platform.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_TEMP_SENSOR_FAILURE
System Log Message function-name: unable to read temperature sensor for fru-name
Description The temperature sensor for the indicated component (field-replaceable unit, or FRU)
either did not respond to a request from the chassis process (chassisd) for a temperature
reading or sent a value that is outside the normal operating range.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_TERM_SIGNAL
System Log Message Received SIGTERM request, shutting down
Copyright © 2010, Juniper Networks, Inc.206
Junos 10.3 System Log Messages Reference