Facility LOG_DAEMON
Cause Either a previous software upgrade did not complete successfully, or the chassisd process
or FRU did not restart after a successful software upgrade.
Action Upgrade the software and reboot the routing platform.
CHASSISD_VOLTAGE_READ_FAILED
System Log Message Unable to read voltage from fru-name (group group-id, address address, channel
voltage-channel)
Description The chassis process (chassisd) could not read voltage data from the indicated component
(field-replaceable unit, or FRU).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_VOLTAGE_SENSOR_INIT
System Log Message Unable to initialize voltage sensor for fru-name (group group-id, address address)
Description The chassis process (chassisd) could not initialize the voltage sensor for the indicated
component (field-replaceable unit, for FRU).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
Copyright © 2010, Juniper Networks, Inc.210
Junos 10.3 System Log Messages Reference