Facility LOG_DAEMON
Action Map only one scheduler map to all the interfaces of a group.
COSD_STREAM_IFD_CREATE_FAILURE
System Log Message Unable to create special master interface device for interface-name
Description The class-of-service (CoS) process (cosd) could not create the indicated internal interface
device, which it needs for application of a chassis scheduler map.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause An internal software failure occurred.
Action Contact your technical support representative.
COSD_TIMER_ERROR
System Log Message Unable to set retry timer for rtsock write operation: error-message
Description The class-of-service (CoS) process (cosd) used a routine from the rtsock library to write
to the kernel, but the kernel did not accept the request. The cosd process could not set
the retry timer for the request, for the indicated reason.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause An internal software failure occurred.
Action Contact your technical support representative.
COSD_TRICOLOR_ALWAYS_ON
System Log Message tri-color is always enabled in this platform. There is no need to explicitly set it.
Description Tri-color marking is always enabled on this platform. There is no need to explicitly set it.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
Action Remove the 'tri-color' configuration statement
Copyright © 2010, Juniper Networks, Inc.224
Junos 10.3 System Log Messages Reference