Description Learning request was dropped because the number of times a MAC address moved to
a different interface exceeded the user-configured limit.
Type Error: An error occurred
Severity alert
Facility LOG_DAEMON
Cause A MAC address moved to a different interface more times per second than the user
configured.
ESWD_MAC_MOVE_LIMIT_EXCEEDED
System Log Message MAC move limit (limit) exceeded at vlan-name for MAC address mac-addresse on interface
interface-name
Description The number of times that a MAC address moved to a different interface within a VLAN
exceeded the user-configured limit.
Type Error: An error occurred
Severity alert
Facility LOG_DAEMON
Cause A MAC address moved to a different interface more times per second than the user
configured.
ESWD_MIRROR_ERROR
System Log Message Mirror version on other Routing Engine is incompatible: error-message
Description The indicated error occurred when the layer2 control protocol process (l2cpd) tried to
establish the nonstop routing mirror connection between the master and standby Routing
Engines.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
Cause The master and standby Routing Engines are running incompatable versions of the JUNOS
software.
Action Update the JUNOS software on the master Routing Engine, standby Routing Engine, or
both, so that they are running compatible versions.
ESWD_MIRROR_VERSION_MISMATCH
System Log Message Mirror versions on Routing Engines are incompatible: mastermaster-is-local has version
master-version, standbystandby-is-local has version standby-version