Description A JUNOS process (mspinfo) could not found any configured and active extension-provider
interfaces.
Type Error: An error occurred
Severity notice
Facility ANY
Cause Possible reasons: can't initialize kcom services.
Action Contact your technical support representative.
LIBMSPRPC_CLIENT_NO_CONNECTION
System Log Message Failed connecting fpc=fpc-slot, pic=pic-slot
Description Remote execution of the command given from the RE to the PIC failed, can not connect
to the PIC.
Type Error: An error occurred
Severity notice
Facility ANY
Cause Possible reasons: a)PIC appears online but is not responding b)msprpc server is not
running on the PIC.
Action Contact your technical support representative.
LIBMSPRPC_CLIENT_NO_REPLY
System Log Message Error executing "command": no reply from the PIC
Description Remote execution of the command given from the RE to the PIC failed, no reply from the
PIC.
Type Error: An error occurred
Severity notice
Facility ANY
Cause Possible reasons: a)wrong command b)insufficient permissions c)wrong arguments
d)PIC appears online but is not responding e)msprpc server is not running on the PIC.
Action Contact your technical support representative.
LIBMSPRPC_CLIENT_PIC_DOWN
System Log Message Interface interface-name is down
Description Remote execution of the command given from the RE to the PIC failed, the PIC is down.
Copyright © 2010, Juniper Networks, Inc.420