Description The task analyzer terminated because an error occurred during the task.
Type Error: An error occurred
Severity error
Facility ANY
PFE_CBF_UNSUPPORTED
System Log Message Internet Processor I does not support CoS-based forwarding
Description The Internet Processor I application-specific integrated circuit (ASIC) does not support
class-of-service (CoS)-based forwarding (CBF).
Type Event: This message reports an event, not an error
Severity warning
Facility ANY
PFE_COS_B2_ONE_CLASS
System Log Message COSMAN: classifier classifier-id-new for ifl index replaces classifer classifier-id-old still
used
Description Only one classifier can be active on a B2-based FPC at any given time.
Type Error: An error occurred
Severity error
Facility ANY
PFE_COS_B2_UNSUPPORTED
System Log Message COSMAN: B2 FPC cannot support classifier type classifier-type-name
Description B2-based FPCs can only handle IP precedence classifiers. They do not support any other
classifier.
Type Error: An error occurred
Severity error
Facility ANY
PFE_FW_DELETE_MISMATCH_ERR
System Log Message Instance mismatch for type (installed-firewall-name != deleted-firewall-name) ifl
logical-interface-index family protocol-family
Description Before a firewall is deleted, it is sanity checked against what is installed in the forwarding
topology. A mismatch was detected between the firewall to be deleted and the forwarding
topology, and the delete operation was canceled.
Type Error: An error occurred