Description The indicated Blocks Extensible Exchange Protocol (BEEP) channel could not be started
for the indicated reason.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
Cause The usual cause is an abnormal operation, which might be described in the system log
message.
SDXD_CONNECT_FAIL
System Log Message Connection to SDX server failed: message
Description The Session and Resource Control (SRC) process (sdxd) could not connect to an SRC
server for the indicated reason.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
Cause There was a network problem or the server was not running.
SDXD_DAEMONIZE_FAIL
System Log Message Aborting, unable to run in the background as a daemon: error-message
Description The Service Deployment System process (sdxd) could not create a version of itself to
run in the background as a daemon.
Type Error: An error occurred
Severity emergency
Facility LOG_DAEMON
SDXD_EVLIB_FAILURE
System Log Message function-name: error-message
Description The Service Deployment System process (sdxd) called the indicated function in the
event library. The function failed with the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause An internal software failure occurred.