Severity error
Facility LOG_DAEMON
SDXD_PID_FILE_UPDATE
System Log Message Unable to update process PID file: error-message
Description The Service Deployment System process (sdxd) attempted to update the file that records
its process ID (PID), which serves to prevent multiple instances of sdxd from running
simultaneously. The attempt failed.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
SDXD_SOCKET_FAILURE
System Log Message operation failed: error-message
Description The Service Deployment System process (sdxd) uses Transmission Control Protocol
(TCP) sockets for communication with the SRC server. The indicated operation, which
might be for socket creation or binding to a local address, failed with the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause An internal software failure occurred.
Action Contact your technical support representative.
Copyright © 2010, Juniper Networks, Inc.592
Junos 10.3 System Log Messages Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 and is the answer not in the manual?

Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010
CategorySoftware
LanguageEnglish

Related product manuals