management process (mgd) discovered that the major parts (for example, '5' in '5.x')
of the version numbers do not match.
Type Error: An error occurred
Severity error
Facility ANY
Cause A recent software upgrade did not complete successfully.
Action Issue the 'show version' command to check the JUNOS version. If necessary, issue the
'request system reboot' command to reboot the routing platform and complete the
software installation.
Cause The database file is corrupted.
Action Contact your technical support representative.
UI_DBASE_MISMATCH_MINOR
System Log Message Database header minor version number mismatch for file 'filename': expecting
expected-value, got received-value
Description For compatibility, the version number recorded in the header of the configuration database
must match the version of JUNOS software running on the routing platform. The
management process (mgd) discovered that the minor parts (for example, '2' in 'x.2')
of the version numbers do not match.
Type Error: An error occurred
Severity error
Facility ANY
Cause A recent software upgrade did not complete successfully.
Action Issue the 'show version' command to check the JUNOS version. If necessary, issue the
'request system reboot' command to reboot the routing platform and complete the
software installation.
Cause The database file is corrupted.
Action Contact your technical support representative.
UI_DBASE_MISMATCH_SEQUENCE
System Log Message Database header sequence numbers mismatch for file 'filename'. If a package has just
been added or deleted, please verify and commit the configuration.
645Copyright © 2010, Juniper Networks, Inc.
Chapter 88: UI System Log Messages