Description The header of the configuration database records the version number of the configuration
schema (possible set of statements) used when the database was created. To prevent
corruption, all JUNOS processes that access the database must use the same schema.
The management process (mgd) discovered that the version number for the JUNOS
software installed on the routing platform does not match the header value.
Type Error: An error occurred
Severity warning
Facility ANY
Cause A recent software upgrade did not complete successfully.
Action Issue the 'show version' command to check the JUNOS version. If necessary, issue the
'request system reboot' command to reboot the routing platform and complete the
software installation.
Cause The database file is corrupted.
Action Contact your technical support representative.
UI_DBASE_MISMATCH_SIZE
System Log Message Database header size mismatch for file 'filename': expecting expected-valuex, got
received-value
Description The header of the configuration database records the database size. The management
process (mgd) discovered that the size of the actual database file does not match the
header value.
Type Error: An error occurred
Severity error
Facility ANY
Cause The database file is corrupted.
Action Contact your technical support representative.
UI_DBASE_OPEN_FAILED
System Log Message Database open failed for file 'filename': reason
Description The management process (mgd) could not open the indicated configuration database
file.
Type Error: An error occurred
Severity error
Facility ANY