Table 27: Component LEDs on the Junos Pulse Gateway (continued)
Possible Causes and Corrective ActionsMeaningStateLED
Normal condition. No action is required.The device is receiving power and is
functioning normally.
GreenPower
LED
Normal condition if the Junos Pulse Gateway is switched
off. No action is required.
If you have not powered off the Junos Pulse Gateway, verify
that the AC power cord from the power source to the device
is not damaged, the socket is in working condition, and the
device has an AC input voltage between 110 and 240 VAC.
The device is not receiving powerOff
On the MAG6610 and MAG6611, the hard drive and RAID status LEDs are located on the
back panel. These LEDs are described in Table 28 on page 100.
Table 28: Hard Drive LEDs on the MAG6610 and MAG6611 Junos Pulse
Gateways
Possible Causes and Corrective
ActionsMeaningStateLED
No action is required.ActivityGreenActivity
No action is required.No activityOff
Replace the RAID hard drive. Contact
Juniper Networks Technical Support.
RAID drive has failedSolid redRAID
Status
No action is required.RAID activityBlinking red
No action is required.RAID drive is functioning
properly
Off
An AC power supply has one bicolor LED on its faceplate. This LED displays information
about the status of the power supply.
Copyright © 2014, Juniper Networks, Inc.100
Junos
®
Pulse Gateway Hardware Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper Junos Pulse MAG2600 and is the answer not in the manual?

Juniper Junos Pulse MAG2600 Specifications

General IconGeneral
BrandJuniper
ModelJunos Pulse MAG2600
CategoryGateway
LanguageEnglish

Related product manuals