EasyManuals Logo

Juniper Junos Pulse MAG2600 User Manual

Juniper Junos Pulse MAG2600
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
NOTE: After powering off a power supply, wait at least 60 seconds before
turning it back on. After powering on a power supply, wait at least 60
seconds before turning it off.
If the system is completely powered off when you power on the power
supply, the Junos Pulse Gateway boots as the power supply completes
its startup sequence.
After a power supply is powered on, it can take up to 60 seconds for status
indicators—such as the status LEDs on the power supply and the show
chassis command display—to indicate that the power supply is functioning
normally. Ignore error indicators that appear during the first 60 seconds.
9. On the external management device connected to the Junos Pulse Gateway, monitor
the startup process to verify that the system has booted properly.
Related
Documentation
Powering Off the Junos Pulse Gateway on page 80
Monitoring the Junos Pulse Gateway Components Using LEDs on page 99
Powering Off the Junos Pulse Gateway
NOTE: After powering off a power supply, wait at least 60 seconds before
turning it back on.
To power off the MAG2600, press the power button located on the front panel.
You can power off the MAG4610, MAG6610 and MAG6611 in one of the following ways:
Graceful shutdown—Press the Power button and hold it 3 to 5 seconds. The device
begins gracefully shutting down the operating system and then powers itself off.
Immediate shutdown—Press the Power button and hold it 15 to 20 seconds. The device
immediately powers itself off without shutting down the operating system.
The power button is located on the back panel of the chassis for the MAG4610, MAG6610
and MAG6611.
Pressing the power button on the MAG-CM060 powers off only the MAG-CM060.
Graceful shutdown—Momentarily press the Power button. The MAG-CM060 begins
gracefully shutting down the operating system and then powers itself off.
Immediate shutdown—Press the Power button on the MAG-CM060 and hold it 5
seconds. The MAG-CM060 immediately powers itself off.
Related
Documentation
Powering On an AC-Powered Junos Pulse Gateway on page 79
Copyright © 2014, Juniper Networks, Inc.80
Junos
®
Pulse Gateway Hardware Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper Junos Pulse MAG2600 and is the answer not in the manual?

Juniper Junos Pulse MAG2600 Specifications

General IconGeneral
BrandJuniper
ModelJunos Pulse MAG2600
CategoryGateway
LanguageEnglish

Related product manuals