Figure 17: Four Post Mounting the Junos Pulse Gateway
•
In a position recessed 2 in. from the front of a 19-in. rack or cabinet by using the mounting
brackets provided with the Junos Pulse Gateway. You can mount the chassis in this
recessed position on four-post racks and cabinets.
The holes in the mounting brackets are placed at 1-U (1.75-in., or 4.45 -cm) apart so that
the Junos Pulse Gateway can be mounted in any rack or cabinet that provides holes
spaced at that distance.
NOTE:
•
If you are installing multiple devices in one rack, install the lowest one first
and then proceed upward in the rack.
Related
Documentation
Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet on page 65•
• Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or Cabinet on
page 67
Using the MAG-RK1U Mounting Kit
The MAG-RK1U mounting kit contains the hardware for rail-mounting your MAG 6610
1-U Junos Pulse Gateway.
The kit includes:
•
2 front rails
•
2 rear rails
•
10 flat-head M4 screws
•
10 medium round-head screws
•
4 flat-head 6-32 screws