CAUTION: Avoid bending fiber-optic cable beyond its minimum bend
radius.An arcsmaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
12. Use one of the following methods to bring the DPC online:
•
Press and hold the corresponding DPC online button on the craft interface until the
green OK LED next to the button lights steadily, in about 5 seconds.
•
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer.
CAUTION: After the OK LED turns green, wait at least 30 seconds before
removing the DPC again, removing a DPC from a different slot, or inserting
a DPC in a different slot.
You can also verify that the DPC is functioning correctly by issuing the show chassis fpc
and show chassis fpc pic-status commands.