PIC 0  Online       MS-DPC PIC
  PIC 1  Online       MS-DPC PIC 
For further description of the output from the command, see the CLI Explorer.
Related
Documentation
MX240 Modular Port Concentrator (MPC) Description on page 77•
• MX240 Modular Port Concentrator (MPC) LEDs on page 80
• Troubleshooting the MX240 MPCs on page 408
• Replacing an MX240 MPC on page 311
Maintaining MX240 PICs
Purpose For optimum router performance, verify the condition of the PICs and PIC cables.
Action On a regular basis:
• Check the LEDs on PIC faceplates. The meaning of the LED states differs for various
PICs. For more information, see the MX Series Interface Module Reference. If the FPC that
houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent
to the Routing Engine.
• Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are
numbered from 0 through 1, left to right:
user@host> show chassis fpc pic-status
  Slot 0   Online       DPC 40x 1GE R
    PIC 0  Online       10x 1GE(LAN)
    PIC 1  Online       10x 1GE(LAN)
    PIC 2  Online       10x 1GE(LAN)
    PIC 3  Online       10x 1GE(LAN)
  Slot 1   Online       MX FPC Type 3
    PIC 0  Online       1x OC-192 SONET
    PIC 1  Online       1x OC-192 SONET
For further description of the output from the command, see the CLI Explorer.
Related
Documentation
MX240 PIC Description on page 59•
• Troubleshooting the MX240 PICs on page 410
• Replacing an MX240 PIC on page 316
• MX240 PIC Serial Number Label on page 427
Maintaining Cables that Connect to MX240 DPCs, MPCs, MICs, or PICs
Purpose For optimum router performance, verify the condition of the cables that connect to the
DPCs, MPCs, MICs, or PICs.
395Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components