CHAPTER 26
Replacing Power System Components
•
Replacing an MX240 AC Normal-Capacity Power Supply on page 335
•
Replacing an MX240 AC Power Supply Cord on page 337
•
Replacing an MX240 DC Normal-Capacity Power Supply on page 338
•
Replacing an MX240 DC Power Supply Cable on page 343
Replacing an MX240 AC Normal-Capacity Power Supply
1.
Removing an MX240 AC Normal-Capacity Power Supply on page 335
2.
Installing an MX240 AC Normal-Capacity Power Supply on page 336
Removing an MX240 AC Normal-Capacity Power Supply
Before you remove a power supply, be aware of the following:
NOTE: The minimum numberofpower supplies mustbepresentinthe router
at all times.
CAUTION: To maintain proper cooling and prevent thermal shutdown of the
operating power supply unit, each power supply slot must contain either a
power supply or a blank panel. If you remove a power supply, you must install
a replacement power supply or a blank panel shortly after the removal.
NOTE: After powering off a power supply, wait at least 60 seconds before
turning it back on.
335Copyright © 2017, Juniper Networks, Inc.