CAUTION: Avoid bending fiber-optic cable beyond its minimum bend
radius.An arcsmaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
13. Use one of the following methods to bring the MPC online:
Press and hold the corresponding MPC online button on the craft interface until the
green OK/FAIL LED next to the button lights steadily, in about 5 seconds.
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer.
CAUTION: After the OK/FAIL LED lights steadily, wait at least 30 seconds
before removing the MPC again, removing an MPC from a different slot,
or inserting an MPC in a different slot.
You can also verify correct MPC and MIC functioning by issuing the show chassis fpc and
show chassis fpc pic-status commands described in “Maintaining MX240 MPCs” on
page 393 and “Maintaining MX240 MICs” on page 393.
Figure 141: Installing an MPC
OK
MASTER
FAN
ONLINE
OFFLINE
0
0
1
0
2
2
1
0
1
1
PEM
FAIL
FAIL
FAIL
FAIL
ESD
OK
OK
OK
ACO/LT
YELLOW ALARM
RED ALARM
NC
NO
C
NC
NO
C
MX240
REO
RE1
0
1
2
3
SCB
SCB
g004913
MPC
Related
Documentation
MX240 Modular Port Concentrator (MPC) Description on page 77
Maintaining MX240 MPCs on page 393
Replacing an MX240 MIC on page 307
MX240 MPC Serial Number Label on page 426
Preventing Electrostatic Discharge Damage to an MX240 Router on page 444