CAUTION: Avoid bending fiber-optic cable beyond its minimum bend
radius.An arcsmaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
8. Use one of the following methods to bring the PIC online:
•
Press the PIC offline/online button until the PIC LED lights green. For a PIC installed
in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
•
Issue the following CLI command:
user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer.
The normal functioning status LED confirms that the PIC is online. You can also verify
correct PIC functioning by issuing the show chassis fpc pic-status command described
in “Maintaining MX240 PICs” on page 395.
Figure 143: Installing a PIC
Related
Documentation
MX240 PIC Description on page 59•
• Maintaining MX240 PICs on page 395
• Troubleshooting the MX240 PICs on page 410
• Replacing an MX240 FPC on page 302
• Preventing Electrostatic Discharge Damage to an MX240 Router on page 444