9. Grasp both ejector handles, and rotate them clockwise simultaneously until the AS
MLC is fully seated.
10. Use one of the following methods to bring the AS MLC online:
Press and hold the AS MLC online/offline button until the green OK LED next to the
button lights steadily, in about 5 seconds. The LEDs and online/offline button for
each AS MLC are located above it on the craft interface.
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer.
CAUTION: Afterthe OK LED lightssteadily, waitat least 30 secondsbefore
removing the AS MLC again, removing an AS MLC from a different slot, or
inserting an AS MLC in a different slot.
You can also verify correct AS MLC and AS MSC or AS MXC functioning by issuing the
show chassis fpc and show chassis fpc pic-status.
Figure 146: Installing an AS MLC
OK
MASTER
FAN
ONLINE
OFFLINE
0
0
1
0
2
2
1
0
1
1
PEM
FAIL
FAIL
FAIL
FAIL
ESD
OK
OK
OK
ACO/LT
YELLOW ALARM
RED ALARM
NC
NO
C
NC
NO
C
MX240
REO
RE1
0
1
2
3
SCB
SCB
g007338
Related
Documentation
Preventing Electrostatic Discharge Damage to an MX240 Router on page 444
Replacing an MX240 AS MSC on page 328
Replacing an MX240 AS MXC on page 331
Replacing an MX240 AS MSC
1.
Removing an MX240 AS MSC on page 329
2.
Installing an MX240 AS MSC on page 330
Copyright © 2017, Juniper Networks, Inc.328
MX240 3D Universal Edge Router Hardware Guide