PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 2 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
For further description of the output from the command, see the CLI Explorer.
Related
Documentation
MX240 Dense Port Concentrator (DPC) Description on page 49•
• MX240 Dense Port Concentrator (DPC) LEDs on page 54
• Maintaining Cables that Connect to MX240 DPCs, MPCs, MICs, or PICs on page 395
• Troubleshooting the MX240 DPCs on page 404
• Replacing an MX240 DPC on page 297
Holding an MX240 DPC
When carrying a DPC, you can hold it either vertically or horizontally.
NOTE: A DPC weighs 14.5 lb (6.6 kg). Be prepared to accept the full weight
of the DPC as you lift it.
To hold a DPC vertically:
1. Orient the DPC so that the faceplate faces you. To verify orientation, confirm that the
text on the DPC is right-side up and the electromagnetic interference (EMI) strip is on
the right-hand side.
2. Place one hand around the DPC faceplate about a quarter of the way down from the
top edge. To avoid deforming the EMI shielding strip, do not press hard on it.
3. Place your other hand at the bottom edge of the DPC.
If the DPC is horizontal before you grasp it, place your left hand around the faceplate and
your right hand along the bottom edge.
To hold a DPC horizontally:
1. Orient the DPC so that the faceplate faces you.
2. Grasp the top edge with your left hand and the bottom edge with your right hand.
Copyright © 2017, Juniper Networks, Inc.384
MX240 3D Universal Edge Router Hardware Guide