Troubleshooting the MX240 MICs
Problem Description: The MICs are not functioning normally.
Solution Check the status of each port on a MIC by looking at the LED located on the MIC
faceplate. For information about the meaning of LED states on different MICs, see the
MX Series Interface Module Reference.
•
• Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The
MIC slots in the MPC are labeled PIC 0/1 and PIC 2/3, left to right:
user@host> show chassis fpc pic-status
Slot 0 Online MPC Type 2 3D EQ
PIC 0 Online 1x 10GE XFP
PIC 1 Online 1x 10GE XFP
Slot 1 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
Slot 2 Online MS-DPC
PIC 0 Online MS-DPC PIC
PIC 1 Online MS-DPC PIC
For further description of the output from the command, see the CLI Explorer.