Serial ID 1000694968
Start time 2007-07-10 12:27:39 PDT
Uptime 1 hour, 40 minutes, 37 seconds
Load averages: 1 minute 5 minute 15 minute
0.11 0.06 0.01
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 46 degrees C / 114 degrees F
CPU temperature 42 degrees C / 107 degrees F
DRAM 2048 MB
Memory utilization 13 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model RE-S-1300
Serial ID 1000694976
Start time 2007-06-19 14:17:00 PDT
Uptime 20 days, 23 hours, 51 minutes, 4 seconds
To check the status of the SCBs, issue the show chassis environment cb command.
The output is similar to the following:
user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 40 degrees C / 104 degrees F
Power 1
1.2 V 1208 mV
1.5 V 1521 mV
1.8 V 1807 mV
2.5 V 2507 mV
3.3 V 3319 mV
5.0 V 5033 mV
12.0 V 12142 mV
1.25 V 1243 mV
3.3 V SM3 3312 mV
5 V RE 5059 mV
12 V RE 11968 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11234 mV
11.3 V bias POE 0 11176 mV
11.3 V bias POE 1 11292 mV
Bus Revision 42
FPGA Revision 1
CB 1 status:
State Online Standby
Temperature 40 degrees C / 104 degrees F
Power 1
1.2 V 1202 mV
1.5 V 1514 mV
1.8 V 1807 mV
2.5 V 2500 mV
381Copyright © 2017, Juniper Networks, Inc.