Troubleshooting 10
Vibratory drive problems and solutions 10.5
10.5 Vibratory drive problems and solutions
Note
• Before you change one of the programming variables, check the
parameter against standards.
Problem Possible Cause Remedy
Vibratory does not
start.
• No setpoint from KCM.
• Safety switch is active.
•
• Power cable is disconnected.
• Failed drive unit.
Enter setpoint at operating unit.
Check safety switch on the feeder
or its connection at KCM.
Check vibratory power cables.
Replace motor.
Check for alarms that might stop
the machine.
Check display status for <Wait>,
<Disa>, <Alsh>.
Check that KCM has power.
Tray runs at
maximum
displacement.
• Displacement sensor has failed.
• Setpoint is too high.
Check signal, replace sensor.
If signals are OK, replace KCM.
Reduce setpoint.
Tray displacement
does not reach
desired value.
• Incorrect vibratory programming.
• Displacement sensor not set
correctly.
Check programming.
Check displacement sensor.
Alv LED is <Off> • No AC power to drive
• Drive has failed
Check input power for proper
connections.
Replace drive.