EasyManua.ls Logo

KEB COMBIVERT F6

KEB COMBIVERT F6
544 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating modes
© 2022 KEB Automation KG
169
21
1fghfh
1
Figure 54: Cyclic synchronous velocity mode
4.8.6.2 Speed settings
The speed setpoints are preset via the objects co16 and co17.
Index
Id-Text
Name
Function
0x2510
co16
(CiA 0x60FF) target velocity
target velocity
Setting the setpoint speed
0x60FF
0x2511
co17
(CiA 0x60B1) velocity offset
velocity offset
Is added to target velocity
0x60B1
The resolution of these objects is depending on the adjusted speed scaling. This is
adjusted via co02 velocity shift factor.
Index
Id-Text
Name
Function
0x2502
co02
velocity shift factor
Determination of the speed resolution for setpoints and ac-
tual values in co, st and pr parameters in the cyclic operat-
ing modes.

Table of Contents

Other manuals for KEB COMBIVERT F6

Related product manuals