9.3.2.2.4 Error messages
Index
Name
Function
0x1001
error register
Displays the error state of the CANopen client
error register
0x1001
Bit
Function
0
General error (is set with all other error messages)
1
Error overcurrent
2
Error overpotential or underpotential
3
Error overtemperature
4
Error communication
5
Error profile specific
6
reserved
7
KEB specific
A value of 0 (no bit set) means: No error
9.3.2.2.5 Speed displays
For the following object there is no KEB specific object in the same resolution:
Index
Sub-Idx
Name
Function
0x6044
0
vl velocity actual
value
Actual speed for speed control (as ru08) but with the reso-
lution 1 = 1rpm (resolution of the velocity modes)
Parameter conform to other fieldbus system standards
Other fieldbus systems which are supported on KEB devices of type F6 and S6 are
VARAN on control type K and PROFINET, POWERLINK and EtherNetIP on control type
A.
Information on these fieldbus systems and the associated parameters can be found in the
Programming Manual | Fieldbus systems .
The Programming manual | Fieldbus systems can be downloaded from the KEB website.
Registration is required.

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals