Operating conditions
538
© 2022 KEB Automation KG
13.4 Operating conditions
Only one recipe download can be executed at the same time. During the recipe down-
load, the start of another will be prevented.
In addition, there are no special starting conditions.
The download can be started by digital inputs or by writing of ud04 start recipe.
Exceptions:
The download of the #pon# file occurs with starting the drive controller (power on
or co09).
The download of the #def# occurs at default set loading (power on or co09, if
co08 has been parameterized accordingly).
During downloading, the same checks are made for each individual write operation, like-
wise a write operation from an external source (e.g., COMBIVIS, external PLC, operator,
etc.). The recipe management processes entries which contain a write request for a pa-
rameter (values WA/WO/RW in column "R/W").
Only write requests with index/subindex addressing are processed. (Default for all gener-
ation 6 devices).
All other entries (blank lines, pause, RO, set-addressed entries) are skipped.

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals