EasyManua.ls Logo

KEB COMBIVERT F6

KEB COMBIVERT F6
544 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating hours counter
208
© 2022 KEB Automation KG
5.9 Operating hours counter
Real time clock
The device has parameters for a real time clock. Time and date must be adapted
by the control with each power-on. The time formats TIME and DATE which are
known from CODESYS are used.
Index
Id-Text
Name
Function
0x2c34
ru52
system date
Datum [DATE_AND_TIME]
0x2c35
ru53
system time
Time [TIME_OF_DAY]
DATE_AND_TIME : 32 bit counter with 1s resolution from 1th January 1970 00:00.
TIME_OF_DAY : 32 bit counter with 1ms resolution from 00:00.
Only ru52 is writable. Internally, ru53 is directly synchronized with ru52.
Operating hours counter
Index
Id-Text
Name
Function
0x2064
de100
hour counter
Operating time in hours
0x2065
de101
mod hour counter
Operating time in hours when modulation is switched on
System counter
Index
Id-Text
Name
Function
0x2123
st35
system counter
Continuous 250us counter

Table of Contents

Other manuals for KEB COMBIVERT F6

Related product manuals