Operating hours counter
208
© 2022 KEB Automation KG
5.9 Operating hours counter
Real time clock
The device has parameters for a real time clock. Time and date must be adapted
by the control with each power-on. The time formats TIME and DATE which are
known from CODESYS are used.
Index
Id-Text
Name
Function
0x2c34
ru52
system date
Datum [DATE_AND_TIME]
0x2c35
ru53
system time
Time [TIME_OF_DAY]
DATE_AND_TIME : 32 bit counter with 1s resolution from 1th January 1970 00:00.
TIME_OF_DAY : 32 bit counter with 1ms resolution from 00:00.
Only ru52 is writable. Internally, ru53 is directly synchronized with ru52.
Operating hours counter
Index
Id-Text
Name
Function
0x2064
de100
hour counter
Operating time in hours
0x2065
de101
mod hour counter
Operating time in hours when modulation is switched on
System counter
Index
Id-Text
Name
Function
0x2123
st35
system counter
Continuous 250us counter

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals