Motor parameterization
© 2022 KEB Automation KG
345
Model control (ASM and SM)
In which speed ranges the model should be active is adjusted with this parameter
in operating modes with motor model.
6.2.16.1 Model deactivation
ds41
model ctrl
0x2429
Bit
Function
Value
Plaintext
Notes
0…2
model (A)SCL
0
dep. on ref/act
speed
Model deactivation in encoderless
operation
1
always on
2
dep. on act speed
3…7
reserved
3…5
model with
encoder
0
dep. on ref/act
speed
Model deactivation in operation with
speed encoder
8
always on
16
dep. on act. speed
24…56
reserved
6…7
reserved
reserved
8…9
low speed ctrl
(A)SCL
0
(A)ViCL
(Asynchron) Vektore Current Close
Loop. Current-controlled operation,
operates with precontrol of the
torque
256
ASiCL
Asynchron Single Current Close
Loop
This operating mode is designed for
stable concentricity at low speeds
and motor operation. The error in the
stator resistance is important for the
stability of the operation, by way
there are deviations from the real
speed under load.
512…768
reserved

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals