New data are written, but not transferred yet
Initialization of standardizations
The data are transferred for the control, but the storage in the
EEPROM is not completed yet
Error occurred in standardization routine:
• Control parameters could not be calculated (motor / in-
verter size not suitable, motor data not associated)
• Rated switching frequency too low
It can be selected between asynchronous and synchronous motor via dr00 motor
type.
an asynchronous motor should be parameterized
an asynchronous motor should be parameterized
synchronous reluctance motor
(SynRM)
The start-up of this motor type is currently only possible in
cooperation with KEB.
Information can be obtained from the sales representative
responsible for you.
The equivalent circuit data (resistance, inductance) must be preset as phase-
phase values.
If only phase values are specified in the data sheet these values must be con-
verted in phase-phase values (depending on the circuit mode) for inverter parame-
ters.
The dr parameters differ in nameplate data, equivalent circuit data (determined of
data sheet or auto-ID) and application-specific data.