Motor parameterization
286
© 2022 KEB Automation KG
Possible errors:
dr57
ident error info
0x2239
Value
Note
Meaning
122
rotor det. cvv curr.
Current stiff could not be executed
123
rotor det. cvv pos.
Encoder position has not turned electrical about min. 12° in the pre-
set direction.
This procedure is not suitable for IPM motors or when using a holding brake!
6.2.3.5.4 Rotor position detection mode five step
Index
Id-Text
Name
Function
0x3602
dd02
rotor detection current
Test signal-current level in % of the rated motor cur-
rent
0x3607
dd07
rotor det. 1.order level
Error threshold for test signal
0x3608
dd08
rot. det. inf. (1.order)
Information content of the test signal
The "five step“ method uses the saturation of the motor for detection of the rotor
position at standstill.
Five different voltage vectors are applied to the motor within a few ms. The current
level to be reached can be preset via parameter dd02. The position of the rotor can
be deducted by means on the current rise times.
dd02 should be set to the maximum permissible motor current, since higher current
causes higher saturation and thus more precise identification.
If this method can be used for the motor, cannot be calculated previously with the
motor data (Ld,Lq).
dd08 indicates the quality of the information content.
Parameter (dd07) defines the level when an error shall be triggered, because the
information content is not sufficient (a level of 5% should be selected as starting
value).
The information content can be different at different rotor positions. Therefore sev-
eral different electrical positions should be tested at start-up.