Motor parameterization
306
© 2022 KEB Automation KG
Index
Id-Text
Name
Function
0x240F
ds15
dyn dec ctrl. fac-
tor
Adjustment of the dynamic proportion of the decoupling: 100% -
ds15 forms the proportion of static decoupling. (Parameter is
only effective if value 32 "compression + dynamic decoupling" is
selected in ds14 for priority).
0x2410
ds16
anti windup speed
level
Activation level of the anti windup limitation of the current con-
trollers. Raising the AW level can increase the dynamic range.
(Parameter is only effective if value 32 "compression + dynamic
decoupling" is selected in ds04 for priority).