Motor parameterization
352
© 2022 KEB Automation KG
Parameterization depending on the operation:
pure motor operation
Parameter
Name
Value
ds63[1]
ASiCL curr. ctrl IsqPt1
3*Tr
ds63[2]
ASiCL slip calculation IsqPt1
3*Tr
ds63[3]
ASiCL curr.ctrl. delay at zero
Tr/20
ds63[4]
ASiCL Rs stab. mode
constant factor (ds63[7])
ds63[7]
Rs stabilisation factor
80%
motor and regenerative operation
Parameter
Name
Value
ds63[1]
ASiCL curr. ctrl IsqPt1
3*Tr/50…3*Tr/10
ds63[2]
ASiCL slip calculation IsqPt1
3*Tr
ds63[3]
ASiCL curr.ctrl. delay at zero
Tr/20
ds63[4]
ASiCL Rs stab. mode
stabilisation mot/gen
ds63[5]
ASiCL Rs stab. high limit
120%
Ds63[6]
ASiCL Rs stab. Low limit
80%
The rotor time constant (Tr in
[ms]) is calculated from:

 

 
 


 


Note:
The inertia and dynamics of the load change are also taken into account in the de-
sign, thus parameterization, here only dependent on the rotor time constant, can
only serve as a guide value.