Loading...
Motor parameterization
© 2022 KEB Automation KG
361
dr55
ident state
0x2237
Value
Name
Note
19
rotor detection (five step)
Rotor position identification according to "constant volt-
age vector", "hf detection" or "five-step" procedure run-
ning (=> see Chapter 6.2.3.5 System offset)
23
least square ident (RsPre)
24
IGBT-model + Rs ident
25
IGBT-model + Rs background calc.