A input = ru78 Analog Output
A input = an44 ANOUT2 display
A input = an47 ANOUT3 display
A input = ru78 Analog Output
A input = an44 ANOUT2 display
A input = an47 ANOUT3 display
AUX = |A| (absolute value of A)
Mapping of REF and AUX
AUX (ru49) and REF (ru48) are limited to +/- 400% after the calculation. Then these two
values can be set to any objects with the following settings.
Determination which object is affected by REF
Scaling of the analog setpoint to the selected object.
Status of the standardization function
Determination to which object AUX acts on
Scaling of the analog setpoint to the selected object.
Status of the standardization function
The address of any object which is to be influenced by the analog values can be adjusted
directly in an31 and an34.
All writable objects that are also permissible for process data are permitted.
If, for example, the setpoint speed shall be preset analog via vl20 target velocity (address
0x2314), an31 = 0x2314 must be adjusted.
The analog setpoint is standardized and by way adapted to the required value range of
the objects with an32 REF norm fact and an35 AUX norm fact.
The values are written with the same standardization functions, over which the objects
are accessible also via bus system.