EasyManuals Logo
Home>KEB>Controller>COMBIVERT F6

KEB COMBIVERT F6 Programming Manual

KEB COMBIVERT F6
544 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #474 background imageLoading...
Page #474 background image
Analog inputs
474
© 2022 KEB Automation KG
an68
PID act value source
Value
Function
Function
0
off
The PID controller is completely deactivated
1
An1
Analog input 1 is actual value source
2
An2
Analog input 2 is actual value source
3
an67
PID actual value is preset via an67 in the range -400.0% ... 400.0%
4
active current
Active current ru11 act active current / rated motor current dr03 corre-
sponds to 100.0%
5
apparent current
Apparent current ru10 act. apparent current / rated motor current dr03 cor-
responds to 100.0%
6
Uic
DC link voltage ru14 act Uic voltage / 1000V corresponds to 100%
7
active power
Active power ru82[2] electrical output power
Rated device power Un * In *  corresponds to 100%
8
actual torque
Actual torque ru24 actual torque / rated motor torque dr09 corresponds to
100%
9
utilization
Inverter utilization = apparent current / rated device current de28
3
ANOUT1
The value of ru78 Analog Out display is the actual value source.
4096 100%
4
ANOUT2
an44 ANOUT2 display is the actual value source.
4096 100%
5
ANOUT3
an47 ANOUT3 display is the actual value source.
4096 100%

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals