EasyManuals Logo

Keysight EDU33210 Series User Manual

Keysight EDU33210 Series
503 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Output a DC Voltage
You can output a constant DC voltage, from -5 V to +5 V into 50 Ω, or -10 V to +10 V into a high impedance load.
1. Press [Waveform] > MORE 1 / 2 > DC > Offset. The Offset value becomes selected.
2. Enter the desired voltage offset. Enter 1.0 with the numeric keypad or knob, and press the V softkey if you used the
keypad.
Set Duty Cycle of a Square Wave
The power-on default for square wave duty cycle is 50%. The duty cycle is limited by the minimum pulse width
specification of 16 ns. The following procedure changes the duty cycle to 75%.
Keysight EDU33210 Series User's Guide
31