LDI Intellectual Property.
Not for secondary distribution or replication, in part or entirety.
DIGISONDE-4D
SYSTEM MANUAL
VERSION 1.2.11
SECTION 5 - SYSTEM SOFTWARE – ANNEX A 5-35
Save Data Flags
Bit 0 Save Raw Data flag
Bit 1 Do Not Save Product Data
Bit 2 Ionogram Data Reduction, when set then databins
with amplitudes ≤ MPA will be lost
Bit 3 Ionogram PGH (Precision Group Height) mode
Notes:
DCART has a global option that can override Save Raw Data
flag selection to produce no raw files or produce raw files for
all available programs.
Option ‘Do not Save Product Data’ is used for testing and
some cases when you do not need to save produced data
Top Range of the search window for the strongest echo
Search window is used to select a subset of ranges (see
NRO) around the strongest echo (199 E-layer, 400 F-layer)
Presently this parameter is used only by Doppler processing
when creating Doppler/Drift data product.
See also: Auto-drift Message Packet
Bottom Range of the search window for the strongest
echo
Search window is used to select a subset of ranges (see
NRO) around the strongest echo (80 E-layer, 200 F-layer)
Presently this parameter is used only by Doppler processing
when creating Doppler/Drift data product.
See also: Auto-drift Message Packet
Number of Ranges to Output
(reduced number of ranges selected around the strongest
echo on each frequency)
Presently this parameter is used only by Doppler processing
when creating Doppler/Drift data product.
Set this parameter to 0 if you want all ranges to be output
Order of Pulse Sequencing: list of 4 IDs from the slowest
changing to the fastest changing index within one CIT.
Available IDs are:
0 = Fine Frequency
1 = Polarization
2 = Integrated Repetition
3 = Complementary Code
Sampling Start Delay
In support of oblique sounding mode
Shall be specified in increments of 5 msec (1500 km)
Digisonde
®
model from UDD
2 = DPS1
3 = DPS4
5 = DPS4D
Transmitter ID
In support of oblique sounding and Tx surveillance modes
For oblique sounding experiments with other DPS transmit-
ters, TX_ID is 000XXX, where XXX is Station ID.
For not oblique sounding this field is equal to ‘ ‘ (6 space
characters).
000000 means UNKNOWN station
Flex List Frequencies (Table of Frequencies,
Table 5A- 7)
Table 5A- 7: Frequency for Flex List (Length 2 Bytes)
Frequency, element of Flex List Frequencies array