Viva Series, Sets of Angles 1505
A screen displays a notice that monitoring is in progress. If necessary, press Cancel to stop
the monitoring process and return to Sets of angles menu.
Refer to "48.2 Sets of Angles" for information about calculations and the viewing of results.
Monitoring interval Description
The dates and times entered define the timeframe for when the monitoring will take place.
The time interval defines the time between the start of each measurement set during the
monitoring period. The interval time begins at the start of a measurement set and ends at
the start of the next measurement set.
Example
Data;
Results;
• The time taken to measure 4 sets of 3 target points in both faces is 10 minutes.
• The measurements will start at 14:00:00 on 03.11.2010.
• At 14:10:00, the first measurement set is complete.
• The instrument will wait until 14:30:00 for the next scheduled measurement set.
• 3 target points • 4 measure sets
• Begin Date: 03.11.2010 • Begin Time: 14:00:00
• End Date: 06.11.2010 • End Time: 14:00:00
• Interval: 30 min