Operating the milking robot
Chapter 5 - page 14
M-HE.002.1003
Resetting the M4USE (optional)
When the buckets are emptied and cleaned, the separation arm must be reset.
For this purpose, press the separation pipeline cleaning key (B6). For more
detailed information see section 2.4.2 ’Control function keys’.
This action deletes the data as indicated in the above screen and allows the
arm, to start filling bucket 1 again with milk from the next separation cow.
Manual separation
With the M4USE (optional) separation arm, you can select if separation milk
(set manual in T4C/X-pert) needs to be separated in a bucket or must be
dumped in a sewer.
When "yes" is selected:
Colostrum will be pumped in the buckets, separation milk will be dumped in
the sewer.
When "no" is selected:
Colostrum and separation milk will be pumped in the buckets. Milk that is set for automatic milk separation
(described below) will always be pumped in the buckets.
Automatic separation
MQC - Colour
MQC - Conductivity
Here you can select if the milk needs to be separated because of an attention
on colour and/or conductivity.
This only works if MQC is installed.
Table 5.1 LED explanation
LED M4USE
OFF All 4 buckets empty
Slowly flashing Some buckets filled with milk
Rapidly flashing All buckets are filled
Manual yes
milk separation
>> Dump
no
Automatic 0
milk separation