9.4.6.7 Flying restart controller
For a quick commissioning, the calculaons and sengs are made automacally during the
mot
or calibraon.
Details
The following parameter is only relevant for the ying restart circuit if an asynchronous motor
is controlled.
Parameter
Address Name / seng range / [default seng] Informaon
0x2BA1:003
(P718.03)
Flying restart circuit: Restart
me
(Flying restart: Restart me)
1 ... [5911]* ... 60000 ms
* Default seng dependent on the model.
Integraon me for controlling the ying restart circuit.
9.4.6.8 SLVC controller
For a quick commissioning, the calculaons and sengs are made automacally during the
mot
or calibraon.
Precondions
The SLVC controller is only eecve in the motor control type "Sensorless vector control
(SLVC)".
Parameter
Address Name / seng range / [default seng] Informaon
0x2B40:001 Gain
0.0000 ... [0.2686]* ... 1000.0000 Hz/
A
* Default seng dependent on the model.
Gain of the SLVC-Q controller.
0x2B40:002 Reset me
1.0 ... [2.3]* ... 2000.0 ms
* Default seng dependent on the model.
Reset me of the SLVC-Q controller.