10.3.2 Digital output 1
Sengs for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in 0x2634:002
(P420.02).
The following sengs are possible for the digital output:
Inversion
Switch-on delay
Cutout delay
DO1
0x4016:0050x4016:006
1
0
1
0x2635 002: 0x4016 004: 0x4016:003
0x2634:002
X3
Trigger
Diagnosc parameters:
The logic s
tatus of the trigger signal is displayed in 0x4016:006.
The logic status of the digital output is displayed in 0x4016:005.
Parameter
Address Name / seng range / [default seng] Informaon
0x2634:002
(P420.02)
Digital outputs funcon: Digital output 1
(Dig.out.funcon: DO1 funcon)
F
or further possible sengs, see parameter
0x2634:001
(P420.01). ^ 211
Assignment of a trigger to digital output 1.
Trigger = FALSE: X3/DO1 set to LOW level.
Trigger = TRUE: X3/DO1 set to HIGH level.
Notes:
An inversion set in 0x2635:002 (P421.02) is taken into consideraon
here.
115 Release holding brake Trigger signal for releasing the holding brake (TRUE = release holding
brake).
Note!
If this trigger is assigned to the relay or a digital output, the deceleraon
mes set for the respecve output are not eecve (are internally set to
"0"). Only the deceleraon me set in 0x2820:012 (P712.12) for closing
the holding brake inuences in this case the me-dependent behaviour
of the output.
4Holding brake control^ 165
0x2635:002
(P421.02)
Inversion of digital outputs: Digital output 1
(DO in
version: DO1 inversion)
Inversion of digital output 1
0 Not inverted
1 Inverted
0x4016:003 Digital output 1: Cutout delay
0.000 ... [0.000] ... 65.535 s
Switch-o delay for digital output 1.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the
deceleraon me set in 0x2820:012 (P712.12)for closing the holding
brake inuences the me-dependent behaviour of the digital output.
0x4016:004 Digital output 1: Switch-on delay
0.000 ... [0.000] ... 65.535 s
Switch-on delay for digital output 1.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the
deceleraon me set in 0x2820:012 (P712.12)for closing the holding
brake inuences the me-dependent behaviour of the digital output.
0x4016:005 Digital output 1: Terminal state
Read only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x4016:006 Digital output 1: Trigger signal state
R
ead only
Display of the logic state of the trigger signal for digital output 1 (without
taking a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
I/O extensions and control connecons
Congure digital outputs
Digit
al output 1