Address Name / seng range / [default seng] Informaon
0x4042:001 ...
0x4042:032
(P751.01 ... 32)
Parameter value set 1: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 1: Set 1 - Value 1 ... Set 1 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 1 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4043:001 ...
0x4043:032
(P752.01 ... 32)
Parameter value set 2: Value of parameter 1 ... Value
of parameter 32
(Par. value set 2: Set 2 - Value 1 ... Set 2 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 2 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4044:001 ...
0x4044:032
(P753.01 ... 32)
Parameter value set 3: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 3: Set 3 - Value 1 ... Set 3 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 3 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4045:001 ...
0x4045:032
(P754.01 ... 32)
Parameter value set 4: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 4: Set 4 - Value 1 ... Set 4 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 4 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4047:001
(P756.01)
Parameter change-over error message: Status
(PSet error msg.: Status)
•
Read only
Error message for the "parameter change-over" funcon.
•
In the e
vent of an error, an error status is shown here, and in
0x4047:002 (P756.02) the number of the list entry in which the error
has occurred is displayed (in connecon with the value set selected).
•
If se
veral errors occur at the same me, only the rst incorrect list
entry will be displayed. Hence, aer eliminaon of the displayed error
and repeated acvaon, more errors may be displayed.
•
The parameter list will always be processed from beginning to end,
even if errors occur in the meanme.
0 No fault
33803 Invalid data type
33804 Range violaon
33806 Invalid index
33813 No element selected
33815 Wring impermissible
33816 Device not inhibited
33829 Invalid subindex
33837 Access impermissible
33860 Parameter not mappable
33865 No subindexes
33876 Parameter not changeable
0x4047:002
(P756.02)
Parameter change-over error message: List entry
(PSe
t error msg.: List entry)
•
Read only
Error message for the "Parameter set changeover" funcon.
•
In the e
vent of an error, the number of the list entry for which the
error displayed in 0x4047:001 (P756.01) has occurred is shown here.
12.2.3 Device commands for parameter change-over
The parameter set can be selected with the device commands "Load parameter set 1" ...
"Load par
ameter set 4".
Details
The change-over via the device commands depends on the acvaon method set in 0x4046
(P755.00):
•
Acvaon method = 1 or 3: Change-over takes place immediately.
•
Acvaon method = 0 or 2: The respecve device command is only executed if the
inverter is disabled.
Parameter
Address Name / seng range / [default seng] Informaon
0x2022:007
(P700.07)
Device commands: Load parameter set 1
(De
vice commands: Load par. set 1)
1 = load value set 1 of the "Parameter change-over" funcon.
•
The par
ameters specied in 0x4041/1...32 are set to the values set in
0x4042/1...32.
•
When the de
vice command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
Addional
funcons
Parameter change-over
Parameter set conguraon