Address Name / seng range / [default seng] Informaon
0x4042:001 ...
0x4042:032
(P751.01 ... 32)
Parameter value set 1: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 1: Set 1 - Value 1 ... Set 1 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 1 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4043:001 ...
0x4043:032
(P752.01 ... 32)
Parameter value set 2: Value of parameter 1 ... Value
of parameter 32
(Par. value set 2: Set 2 - Value 1 ... Set 2 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 2 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4044:001 ...
0x4044:032
(P753.01 ... 32)
Parameter value set 3: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 3: Set 3 - Value 1 ... Set 3 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 3 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4045:001 ...
0x4045:032
(P754.01 ... 32)
Parameter value set 4: Value of parameter 1 ... Value
of par
ameter 32
(Par. value set 4: Set 4 - Value 1 ... Set 4 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 4 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4047:001
(P756.01)
Parameter change-over error message: Status
(PSet error msg.: Status)
Read only
Error message for the "parameter change-over" funcon.
In the e
vent of an error, an error status is shown here, and in
0x4047:002 (P756.02) the number of the list entry in which the error
has occurred is displayed (in connecon with the value set selected).
If se
veral errors occur at the same me, only the rst incorrect list
entry will be displayed. Hence, aer eliminaon of the displayed error
and repeated acvaon, more errors may be displayed.
The parameter list will always be processed from beginning to end,
even if errors occur in the meanme.
0 No fault
33803 Invalid data type
33804 Range violaon
33806 Invalid index
33813 No element selected
33815 Wring impermissible
33816 Device not inhibited
33829 Invalid subindex
33837 Access impermissible
33860 Parameter not mappable
33865 No subindexes
33876 Parameter not changeable
0x4047:002
(P756.02)
Parameter change-over error message: List entry
(PSe
t error msg.: List entry)
Read only
Error message for the "Parameter set changeover" funcon.
In the e
vent of an error, the number of the list entry for which the
error displayed in 0x4047:001 (P756.01) has occurred is shown here.
12.2.3 Device commands for parameter change-over
The parameter set can be selected with the device commands "Load parameter set 1" ...
"Load par
ameter set 4".
Details
The change-over via the device commands depends on the acvaon method set in 0x4046
(P755.00):
Acvaon method = 1 or 3: Change-over takes place immediately.
Acvaon method = 0 or 2: The respecve device command is only executed if the
inverter is disabled.
Parameter
Address Name / seng range / [default seng] Informaon
0x2022:007
(P700.07)
Device commands: Load parameter set 1
(De
vice commands: Load par. set 1)
1 = load value set 1 of the "Parameter change-over" funcon.
The par
ameters specied in 0x4041/1...32 are set to the values set in
0x4042/1...32.
When the de
vice command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
Addional
funcons
Parameter change-over
Parameter set conguraon
234